"fieldbus.spoe" block — settings that apply only to the SPoE driver.
More...
#include <config.h>
Public Attributes | |
| std::string | mode = "monitor" |
| uint32_t | watchdogMs = 75 |
| uint16_t | port = 8080 |
| The TCP port of the SPoE server on every drive. | |
"fieldbus.spoe" block — settings that apply only to the SPoE driver.
| std::string SpoeConfig::mode = "monitor" |
"monitor" | "control". In Monitor mode a PLC owns the drive's state, and Motion Master only parametrises and observes. Monitor is the default, because it cannot fault a drive that a PLC controls.
| uint16_t SpoeConfig::port = 8080 |
The TCP port of the SPoE server on every drive.
| uint32_t SpoeConfig::watchdogMs = 75 |
Control mode only. The drive faults when no SPoE message arrives for this long. The firmware accepts 50 ms at least. Firmware with SPoE protocol 1.0 cannot set it and uses a fixed watchdog.